Export limit exceeded: 24822 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search vulnerabilities

Results 24,822

Export CSV
CVE-2024-43656

A backup can be manipulated and then restored to create arbitrary files inside the <redacted> directory. A CGI script can be added to the web directory this way, allowing for full remote code execution.

Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).

CVSS 4.0 · 9.3 Critical EPSS 1.5% KEV · Not listed
Vendors
—
Products
—
CVE-2024-43657

When uploading new firmware, a shell script inside a firmware file is executed during its processing. This can be used to craft a custom firmware file with a custom script with arbitrary code, which will then be executed on the charging station.

Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).

CVSS 4.0 · 9.3 Critical EPSS 1.5% KEV · Not listed
Vendors
—
Products
—
CVE-2024-43688

cron/entry.c in vixie cron before 9cc8ab1, as used in OpenBSD 7.4 and 7.5, allows a heap-based buffer underflow and memory corruption. NOTE: this issue was introduced during a May 2023 refactoring.

CVSS 3.1 · 7.3 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2024-45242

EnGenius ENH1350EXT A8J-ENH1350EXT devices through 3.9.3.2_c1.9.51 allow (blind) OS Command Injection via shell metacharacters to the Ping or Speed Test utility. During the time of initial setup, the device creates an open unsecured network whose admin panel is configured with the default credentials of admin/admin. An unauthorized attacker in proximity to the Wi-Fi network can exploit this window of time to execute arbitrary OS commands with root-level permissions.

CVSS 3.1 · 7.8 High EPSS 35.4% KEV · Not listed
Vendors
CVE-2024-45251

Elsight – CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

Elsight – CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

CVSS 3.1 · 9.8 Critical EPSS 1.0% KEV · Not listed
Vendors
Products
CVE-2024-45252

Elsight – CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

Elsight – CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

CVSS 3.1 · 9.8 Critical EPSS 1.0% KEV · Not listed
Vendors
Products
CVE-2024-45288

Multiple vulnerabilities in libnv

A missing null-termination character in the last element of an nvlist array string can lead to writing outside the allocated buffer.

CVSS 3.1 · 8.4 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2021-4470

TG8 Firewall Unauthenticated RCE via runphpcmd.php

TG8 Firewall contains a pre-authentication remote code execution vulnerability in the runphpcmd.php endpoint. The syscmd POST parameter is passed directly to a system command without validation and executed with root privileges. A remote, unauthenticated attacker can supply crafted values to execute arbitrary operating system commands as root, resulting in full device compromise.

CVSS 4.0 · 9.3 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2021-33633

Command Injection in aops-ceres

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in openEuler aops-ceres on Linux allows Command Injection. This vulnerability is associated with program files ceres/function/util.Py. This issue affects aops-ceres: from 1.3.0 through 1.4.1.

CVSS 3.1 · 7.3 High EPSS < 1% KEV · Not listed
Vendors
—
Products
—
CVE-2023-22351

Out-of-bounds write in UEFI firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access.

CVSS 4.0 · 6.9 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2021-4466

IPCop <= 2.1.9 Authenticated RCE

IPCop versions up to and including 2.1.9 contain an authenticated remote code execution vulnerability within the web-based administration interface. The email configuration component inserts user-controlled values, including the EMAIL_PW parameter, directly into system-level operations without proper input sanitation. By modifying the email password field to include shell metacharacters and issuing a save-and-test-mail action, an authenticated attacker can execute arbitrary operating system commands with the privileges of the web interface, resulting in full system compromise.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-29929

Buffer Overflow vulnerability found in Kemptechnologies Loadmaster before v.7.2.60.0 allows a remote attacker to casue a denial of service via the libkemplink.so, isreverse library.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Products
CVE-2023-1082

Welotec: Command injection vulnerability in TK500v1 router series

An remote attacker with low privileges can perform a command injection which can lead to root access.

CVSS 3.1 · 8.8 High EPSS < 1% KEV · Not listed
Vendors
—
Products
—
CVE-2009-20011

ContentKeeper Web Appliance < 125.10 RCE via mimencode

ContentKeeper Web Appliance (now maintained by Impero Software) versions prior to 125.10 are vulnerable to remote command execution due to insecure handling of file uploads via the mimencode CGI utility. The vulnerability allows unauthenticated attackers to upload and execute arbitrary scripts as the Apache user. Additionally, the exploit can optionally escalate privileges by abusing insecure PATH usage in the benetool binary, resulting in root-level access if successful.

CVSS 4.0 · 10 Critical EPSS 2.1% KEV · Not listed
Products
CVE-2025-11266

Grassroots DICOM (GDCM) Out-of-bounds Write

An out-of-bounds write vulnerability exists in the Grassroots DICOM library (GDCM). The issue is triggered during parsing of a malformed DICOM file containing encapsulated PixelData fragments (compressed image data stored as multiple fragments). This vulnerability leads to a segmentation fault caused by an out-of-bounds memory access due to unsigned integer underflow in buffer indexing. It is exploitable via file input, simply opening a crafted malicious DICOM file is sufficient to trigger the crash, resulting in a denial-of-service condition.

CVSS 4.0 · 6.8 Medium EPSS < 1% KEV · Not listed
CVE-2024-30804

An issue discovered in the DeviceIoControl component in ASUS Fan_Xpert before v.10013 allows an attacker to execute arbitrary code via crafted IOCTL requests.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2025-52573

Command Injection in MCP Server ios-simulator-mcp

iOS Simulator MCP Server (ios-simulator-mcp) is a Model Context Protocol (MCP) server for interacting with iOS simulators. Versions prior to 1.3.3 are written in a way that is vulnerable to command injection vulnerability attacks as part of some of its MCP Server tool definition and implementation. The MCP Server exposes the tool `ui_tap` which relies on Node.js child process API `exec` which is an unsafe and vulnerable API if concatenated with untrusted user input. LLM exposed user input for `duration`, `udid`, and `x` and `y` args can be replaced with shell meta-characters like `;` or `&&` or others to change the behavior from running the expected command `idb` to another command. When LLMs are tricked through prompt injection (and other techniques and attack vectors) to call the tool with input that uses special shell characters such as `; rm -rf /tmp;#` and other payload variations, the full command-line text will be interepted by the shell and result in other commands except of `ps` executing on the host running the MCP Server. Version 1.3.3 contains a patch for the issue.

CVSS 3.1 · 6 Medium EPSS < 1% KEV · Not listed
Vendors
—
Products
—
CVE-2025-34044

WIFISKY 7-Layer Flow Control Router Remote Command Execution

A remote command injection vulnerability exists in the confirm.php interface of the WIFISKY 7-layer Flow Control Router via a specially-crafted HTTP GET request to the t parameter. Insufficient input validation allows unauthenticated attackers to execute arbitrary OS commands. Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-25 UTC.

CVSS 4.0 · 9.4 Critical EPSS 3.8% KEV · Not listed
Vendors
—
Products
—
CVE-2025-3128

Mitsubishi Electric Europe smartRTU OS Command Injection

A remote unauthenticated attacker who has bypassed authentication could execute arbitrary OS commands to disclose, tamper with, destroy or delete information in Mitsubishi Electric smartRTU, or cause a denial-of service condition on the product.

CVSS 4.0 · 9.3 Critical EPSS < 1% KEV · Not listed
Products