Jenkins AsakusaSatellite Plugin 0.1.1 and earlier does not mask AsakusaSatellite API keys displayed on the job configuration form, increasing the potential for attackers to observe and capture them.
Export limit exceeded: 10960 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search vulnerabilities
IBM Cognos Analytics information disclosure
IBM Cognos Analytics 11.1.7, 11.2.0, and 11.2.1 could be vulnerable to sensitive information exposure by passing API keys to log files. If these keys contain sensitive information, it could lead to further attacks. IBM X-Force ID: 240450.
Pentaminds CuroVMS v2.0.1 was discovered to contain exposed credentials.
SolarWinds Security Event Manager Deserialization of Untrusted Data Remote Code Execution Vulnerability
The SolarWinds Security Event Manager was susceptible to Remote Code Execution Vulnerability. This vulnerability allows an unauthenticated user to abuse SolarWinds’ service, resulting in remote code execution.
The system tool has inconsistent serialization and deserialization. Successful exploitation of this vulnerability will cause unauthorized startup of components.
Rockwell Automation ISaGRAF5 Runtime Unprotected Storage of Credentials
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure.
Rockwell Automation Connected Components Workbench Deserialization of Untrusted Data
Rockwell Automation Connected Components Workbench v12.00.00 and prior does not limit the objects that can be deserialized. This vulnerability allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in remote code execution. This vulnerability requires user interaction to be successfully exploited.
ICSA-22-104-03 Red Lion DA50N
The weak password on the web user interface can be exploited via HTTP or HTTPS. Once such access has been obtained, the other passwords can be changed. The weak password on Linux accounts can be accessed via SSH or Telnet, the former of which is by default enabled on trusted interfaces. While the SSH service does not support root login, a user logging in using either of the other Linux accounts may elevate to root access using the su command if they have access to the associated password.
Rockwell Automation ISaGRAF Deserialization of Untrusted Data
Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited
Cognex In-Sight OPC Server - Deserialization of Untrusted Data
The affected Cognex product, the In-Sight OPC Server versions v5.7.4 (96) and prior, deserializes untrusted data, which could allow a remote attacker access to system level permission commands and local privilege escalation.
ISaGRAF Workbench Deserialization of Untrusted Data CWE-502
Rockwell Automation ISaGRAF Workbench software versions 6.0 through 6.6.9 are affected by a Deserialization of Untrusted Data vulnerability. ISaGRAF Workbench does not limit the objects that can be deserialized. This vulnerability allows attackers to craft a malicious serialized object that, if opened by a local user in ISaGRAF Workbench, may result in remote code execution. This vulnerability requires user interaction to be successfully exploited.
Measuresoft ScadaPro Server and Client Link Following
Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow privilege escalation..
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote code execution.
An issue was discovered in Elspec G5 digital fault recorder versions 1.1.4.15 and before. Unauthenticated directory listing can occur: the web interface cay be abused be an attacker get a better understanding of the operating system.
Fresenius Kabi Agilia Connect Infusion System insufficiently protected credentials
The web application on Agilia Link+ version 3.0 implements authentication and session management mechanisms exclusively on the client-side and does not protect authentication attributes sufficiently.
Fresenius Kabi Agilia Connect Infusion System exposure of information through directory listing
Fresenius Kabi Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 has the option for automated indexing (directory listing) activated. When accessing a directory, a web server delivers its entire content in HTML form. If an index file does not exist and directory listing is enabled, all content of the directory will be displayed, allowing an attacker to identify and access files on the server.
Fresenius Kabi Agilia Connect Infusion System plaintext storage of a password
An attacker with physical access to the host can extract the secrets from the registry and create valid JWT tokens for the Fresenius Kabi Vigilant MasterMed version 2.0.1.3 application and impersonate arbitrary users. An attacker could manipulate RabbitMQ queues and messages by impersonating users.
Fresenius Kabi Agilia Connect Infusion System files or directories accessible to external parties
Fresenius Kabi Agilia SP MC WiFi vD25 and prior has a default configuration page accessible without authentication. An attacker may use this functionality to change the exposed configuration values such as network settings.
Airspan Networks Mimosa Deserialization of Untrusted Data
MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 has a deserialization function that does not validate or check the data, allowing arbitrary classes to be created.
Rockwell Automation FactoryTalk AssetCentre Deserialization of Untrusted Data
Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier components contain .NET remoting endpoints that deserialize untrusted data without sufficiently verifying that the resulting data will be valid. This vulnerability may allow a remote, unauthenticated attacker to gain full access to the FactoryTalk AssetCentre main server and all agent machines.