Export limit exceeded: 56069 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search vulnerabilities

Results 56,069

Export CSV
CVE-2018-14824

Delta Electronics Delta Industrial Automation PMSoft v2.11 or prior has an out-of-bounds read vulnerability that can be executed when processing project files, which may allow an attacker to read confidential information.

CVSS 3.0 · 6.5 Medium EPSS 2.0% KEV · Not listed
Vendors
CVE-2018-14821

Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote, unauthenticated threat actor to intentionally send a malformed CIP packet to Port 44818, causing the RSLinx Classic application to terminate. The user will need to manually restart the software to regain functionality.

CVSS 3.0 · 7.5 High EPSS 4.5% KEV · Not listed
Products
CVE-2018-14818

WECON Technology Co., Ltd. PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior have a stack-based buffer overflow vulnerability which may allow remote code execution.

CVSS 3.1 · 9.8 Critical EPSS 3.5% KEV · Not listed
Vendors
CVE-2018-14816

Advantech WebAccess 8.3.1 and earlier has several stack-based buffer overflow vulnerabilities that have been identified, which may allow an attacker to execute arbitrary code.

CVSS 3.1 · 9.8 Critical EPSS 4.1% KEV · Not listed
Vendors
Products
CVE-2018-14814

WECON Technology PI Studio HMI versions 4.1.9 and prior and PI Studio versions 4.2.34 and prior lacks proper validation of user-supplied data, which may result in a read past the end of an allocated object.

CVSS 3.0 · 6.5 Medium EPSS 1.5% KEV · Not listed
Vendors
CVE-2018-14807

A stack-based buffer overflow vulnerability in Opto 22 PAC Control Basic and PAC Control Professional versions R10.0a and prior may allow remote code execution.

CVSS 3.1 · 9.8 Critical EPSS 3.1% KEV · Not listed
Vendors
Products
CVE-2018-14802

Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly check user-supplied comments which may allow for arbitrary remote code execution.

CVSS 3.0 · 9.8 Critical EPSS 3.6% KEV · Not listed
Vendors
Products
CVE-2018-14800

Delta Electronics ISPSoft version 3.0.5 and prior allow an attacker, by opening a crafted file, to cause the application to read past the boundary allocated to a stack object, which could allow execution of code under the context of the application.

CVSS 3.0 · 7.8 High EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2018-14798

Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly parse FNC files that may allow for information disclosure.

CVSS 3.0 · 5.3 Medium EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2018-14793

DeltaV Versions 11.3.1, 12.3.1, 13.3.0, 13.3.1, and R5 is vulnerable to a buffer overflow exploit through an open communication port to allow arbitrary code execution.

CVSS 3.0 · 8.8 High EPSS 1.0% KEV · Not listed
Vendors
Products
CVE-2018-14792

WECON PLC Editor version 1.3.3U may allow an attacker to execute code under the current process when processing project files.

CVSS 3.0 · 6.3 Medium EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2018-14790

Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. A buffer over-read vulnerability may allow remote code execution on the device.

CVSS 3.0 · 9.8 Critical EPSS 5.4% KEV · Not listed
Vendors
Products
CVE-2018-14780

An out-of-bounds read issue was discovered in the Yubico-Piv 1.5.0 smartcard driver. The file lib/ykpiv.c contains the following code in the function `_ykpiv_fetch_object()`: {% highlight c %} if(sw == SW_SUCCESS) { size_t outlen; int offs = _ykpiv_get_length(data + 1, &outlen); if(offs == 0) { return YKPIV_SIZE_ERROR; } memmove(data, data + 1 + offs, outlen); *len = outlen; return YKPIV_OK; } else { return YKPIV_GENERIC_ERROR; } {% endhighlight %} -- in the end, a `memmove()` occurs with a length retrieved from APDU data. This length is not checked for whether it is outside of the APDU data retrieved. Therefore the `memmove()` could copy bytes behind the allocated data buffer into this buffer.

CVSS 3.0 · 4.6 Medium EPSS < 1% KEV · Not listed
Vendors