{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2024-1628", "assignerOrgId": "171caf72-b841-4e04-a68e-93493aff2b94", "state": "PUBLISHED", "assignerShortName": "GEHC", "dateReserved": "2024-02-19T15:23:20.113Z", "datePublished": "2024-05-14T16:04:57.780Z", "dateUpdated": "2024-08-01T18:48:21.580Z"}, "containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "product": "Venue", "vendor": "GE HealthCare", "versions": [{"status": "affected", "version": "R1"}, {"status": "affected", "version": "R2"}, {"lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom"}, {"lessThanOrEqual": "R4.3", "status": "affected", "version": "R4", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Venue Go", "vendor": "GE HealthCare", "versions": [{"status": "affected", "version": "R2"}, {"lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom"}, {"lessThanOrEqual": "R4.3", "status": "affected", "version": "R4", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Venue Fit", "vendor": "GE HealthCare", "versions": [{"lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom"}, {"lessThanOrEqual": "R4.3", "status": "affected", "version": "R4", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "LOGIQ e", "vendor": "GE HealthCare", "versions": [{"lessThanOrEqual": "R9.1.4", "status": "affected", "version": "R7", "versionType": "custom"}, {"lessThanOrEqual": "R10.1.3", "status": "affected", "version": "R8", "versionType": "custom"}, {"lessThanOrEqual": "R11.0.3", "status": "affected", "version": "R9", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "LOGIQ He", "vendor": "GE HealthCare", "versions": [{"lessThanOrEqual": "R9.3.1", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Vivid E", "vendor": "GE HealthCare", "versions": [{"lessThan": "206", "status": "affected", "version": "E95", "versionType": "custom"}, {"lessThan": "206", "status": "affected", "version": "E90", "versionType": "custom"}, {"lessThan": "206", "status": "affected", "version": "E80", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Vivid S", "vendor": "GE HealthCare", "versions": [{"lessThan": "206", "status": "affected", "version": "70N", "versionType": "custom"}, {"lessThan": "206", "status": "affected", "version": "60N", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Vivid T", "vendor": "GE HealthCare", "versions": [{"lessThan": "206", "status": "affected", "version": "T8", "versionType": "custom"}, {"lessThan": "206", "status": "affected", "version": "T9", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Vivid iq", "vendor": "GE HealthCare", "versions": [{"lessThan": "206", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Voluson Expert 16", "vendor": "GE HealthCare", "versions": [{"status": "affected", "version": "0"}, {"lessThan": "Ext1", "status": "affected", "version": "BT24", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Voluson Expert 18", "vendor": "GE HealthCare", "versions": [{"status": "affected", "version": "0"}, {"lessThan": "Ext1", "status": "affected", "version": "BT24", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Voluson Expert 22", "vendor": "GE HealthCare", "versions": [{"status": "affected", "version": "0"}, {"lessThan": "Ext1", "status": "affected", "version": "BT24", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Voluson SWIFT", "vendor": "GE HealthCare", "versions": [{"status": "affected", "version": "0"}, {"status": "affected", "version": "BT24"}]}, {"defaultStatus": "unaffected", "product": "Invenia ABUS 2.0", "vendor": "GE HealthCare", "versions": [{"lessThanOrEqual": "2.2.7", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "LOGIQ E10", "vendor": "GE HealthCare", "versions": [{"lessThan": "R3.2.0", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "LOGIQ E10s", "vendor": "GE HealthCare", "versions": [{"lessThan": "R3.2.0", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "LOGIQ Fortis", "vendor": "GE HealthCare", "versions": [{"lessThan": "R3.2.0", "status": "affected", "version": "0", "versionType": "custom"}]}], "credits": [{"lang": "en", "type": "finder", "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"}], "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "OS command injection vulnerabilities in GE HealthCare ultrasound devices"}], "value": "OS command injection vulnerabilities in GE HealthCare ultrasound devices"}], "impacts": [{"capecId": "CAPEC-6", "descriptions": [{"lang": "en", "value": "CAPEC-6 Argument Injection"}]}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "171caf72-b841-4e04-a68e-93493aff2b94", "shortName": "GEHC", "dateUpdated": "2024-05-14T16:04:57.780Z"}, "references": [{"url": "https://securityupdate.gehealthcare.com/"}], "source": {"discovery": "EXTERNAL"}, "title": "OS command injection vulnerabilities in GE HealthCare ultrasound devices", "x_generator": {"engine": "Vulnogram 0.1.0-dev"}}, "adp": [{"title": "CISA ADP Vulnrichment", "metrics": [{"other": {"type": "ssvc", "content": {"id": "CVE-2024-1628", "role": "CISA Coordinator", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "total"}], "version": "2.0.3", "timestamp": "2024-05-16T16:10:00.517201Z"}}}], "affected": [{"cpes": ["cpe:2.3:a:ge_healthcare:venue:*:*:*:*:*:*:*:*"], "vendor": "ge_healthcare", "product": "venue", "versions": [{"status": "affected", "version": "multiple versions"}], "defaultStatus": "unknown"}, {"cpes": ["cpe:2.3:a:ge_healthcare:vivid:*:*:*:*:*:*:*:*"], "vendor": "ge_healthcare", "product": "vivid", "versions": [{"status": "affected", "version": "multiple versions"}], "defaultStatus": "unknown"}, {"cpes": ["cpe:2.3:a:ge_healthcare:voluson:*:*:*:*:*:*:*:*"], "vendor": "ge_healthcare", "product": "voluson", "versions": [{"status": "affected", "version": "multiple versions"}], "defaultStatus": "unknown"}, {"cpes": ["cpe:2.3:a:ge_healthcare:logiq:*:*:*:*:*:*:*:*"], "vendor": "ge_healthcare", "product": "logiq", "versions": [{"status": "affected", "version": "multiple versions"}], "defaultStatus": "unknown"}], "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-06-04T18:01:30.939Z"}}, {"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-01T18:48:21.580Z"}, "title": "CVE Program Container", "references": [{"url": "https://securityupdate.gehealthcare.com/", "tags": ["x_transferred"]}]}]}}