Insecure permissions
Coredump binaries in Toshiba printers have incorrect permissions. A local attacker can steal confidential information. As for the affected products/models/versions, see the reference URL.
Coredump binaries in Toshiba printers have incorrect permissions. A local attacker can steal confidential information. As for the affected products/models/versions, see the reference URL.
Obsidian GitHub Copilot Plugin versions prior to 1.1.7 store Github API token in cleartext form. As a result, an attacker may perform unauthorized operations on the linked Github account.
Components of the YoSmart YoLink ecosystem through 2025-10-02 leverage unencrypted MQTT to communicate over the internet. An attacker with the ability to monitor network traffic could therefore obtain sensitive information or tamper with the traffic to control affected devices. This affects YoLink Hub 0382, YoLink Mobile Application 1.40.41, and YoLink MQTT Broker. NOTE: The vendor states that the vulnerability described (related to insecure transmission) only impacts the legacy mobile application logic, not the Hub hardware or firmware. The Hub functions solely as a pass-through (transparent gateway) for LoRa wireless data and does not inspect or process the application layer data.
Toshiba printers will display the password of the admin user in clear-text and additional passwords when sending 2 specific HTTP requests to the internal API. An attacker stealing the cookie of an admin or abusing a XSS vulnerability can recover this password in clear-text and compromise the printer. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point. https://www.toshibatec.com/contacts/products/ As for the affected products/models/versions, see the reference URL.
Missing encryption of sensitive data in Korenix JetPort 5601v3 allows Eavesdropping.This issue affects JetPort 5601v3: through 1.2.
General Industrial Controls Lynx+ Gateway is vulnerable to a cleartext transmission vulnerability that could allow an attacker to observe network traffic to obtain sensitive information, including plaintext credentials.
Under certain circumstances, attacker can capture the network key, read or write encrypted packets on the PowerG network.
CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that exposes test credentials in the firmware binary
A problem with the ActiveMQ integration for both Cortex XSOAR and Cortex XSIAM can result in the cleartext exposure of the configured ActiveMQ credentials in log bundles.
The YoSmart YoLink Smart Hub firmware 0382 is unencrypted, and data extracted from it can be used to determine network access credentials.
Vulnerable data in transit in GE HealthCare EchoPAC products
A vulnerability has been found in vLLM AIBrix 0.2.0 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file pkg/plugins/gateway/prefixcacheindexer/hash.go of the component Prefix Caching. The manipulation leads to insufficiently random values. The complexity of an attack is rather high. The exploitation appears to be difficult. Upgrading to version 0.3.0 is able to address this issue. It is recommended to upgrade the affected component.
A vulnerability has been found in Coinomi up to 1.7.6. This issue affects some unknown processing. Such manipulation leads to cleartext transmission of sensitive information. The attack can be launched remotely. This attack is characterized by high complexity. The exploitability is assessed as difficult. The exploit has been disclosed to the public and may be used. The vendor replied with: "(...) there isn't any security implication associated with your findings."
Cleartext transmission of sensitive information for some BigDL software maintained by Intel(R) before version 2.5.0 may allow an authenticated user to potentially enable denial of service via adjacent access.
Sensitive data could be exposed to non- privileged users in a configuration file. Local access to the computer with a low- privileged account is required to access the configuration file containing the sensitive data.
Hathway Skyworth Router CM5100-511 v4.1.1.24 was discovered to store sensitive information about USB and Wifi connected devices in plaintext.
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected systems transmit client-side resources without proper cryptographic protection. This could allow an attacker to eavesdrop on and modify resources in transit. A successful exploit requires an attacker to be in the network path between the RTLS Locating Manager server and a client (MitM).
Local Deep Research is an AI-powered research assistant for deep, iterative research. Versions 0.2.0 through 0.6.7 stored confidential information, including API keys, in a local SQLite database without encryption. This behavior was not clearly documented outside of the database architecture page. Users were not given the ability to configure the database location, allowing anyone with access to the container or host filesystem to retrieve sensitive data in plaintext by accessing the .db file. This is fixed in version 1.0.0.
Webservice API endpoints for Assisted Service Module within SAP Commerce Cloud has information disclosure vulnerability. When an authorized agent searches for customer to manage their accounts, the request url includes customer data and it is recorded in server logs. If an attacker impersonating as authorized admin visits such server logs, then they get access to the customer data. The amount of leaked confidential data however is extremely limited, and the attacker has no control over what data is leaked.
The HI-SCAN 6040i Hitrax HX-03-19-I was discovered to transmit user credentials in cleartext over the GIOP protocol. This allows attackers to possibly gain access to sensitive information via a man-in-the-middle attack.