Search vulnerabilities

Results 324

Export CSV
CVE-2025-2026

The NPort 6100-G2/6200-G2 Series is affected by a high-severity vulnerability (CVE-2025-2026) that allows remote attackers to execute a null byte injection through the device’s web API. This may lead to an unexpected device reboot and result in a denial-of-service (DoS) condition. An authenticated remote attacker with web read-only privileges can exploit the vulnerable API to inject malicious input. Successful exploitation may cause the device to reboot, disrupting normal operations and causing a temporary denial of service.

CVSS 4.0 · 7.1 High EPSS < 1% KEV · Not listed
Vendors
CVE-2025-5191

Unquoted Search Path Vulnerability in the Utility for Industrial Computers (Windows)

An Unquoted Search Path vulnerability has been identified in the utility for Moxa’s industrial computers (Windows). Due to the unquoted path configuration in the SerialInterfaceService.exe utility, a local attacker with limited privileges could place a malicious executable in a higher-priority directory within the search path. When the Serial Interface service starts, the malicious executable could be run with SYSTEM privileges. Successful exploitation could allow privilege escalation or enable an attacker to maintain persistence on the affected system. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality, integrity, or availability within any subsequent systems.

CVSS 4.0 · 7.3 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2025-1977

The NPort 6100-G2/6200-G2 Series is affected by an execution with unnecessary privileges vulnerability (CVE-2025-1977) that allows an authenticated user with read-only access to perform unauthorized configuration changes through the MCC (Moxa CLI Configuration) tool. The issue can be exploited remotely over the network with low-attack complexity and no user interaction but requires specific system conditions or configurations to be present. Successful exploitation may result in changes to device settings that were not intended to be permitted for the affected user role, potentially leading to a high impact on the confidentiality, integrity, and availability of the device. No impact on other systems has been identified.

CVSS 4.0 · 7.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2025-6892

An Incorrect Authorization vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in the API authentication mechanism allows unauthorized access to protected API endpoints, including those intended for administrative functions. This vulnerability can be exploited after a legitimate user has logged in, as the system fails to properly validate session context or privilege boundaries. An attacker may leverage this flaw to perform unauthorized privileged operations. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2026-4483

Exposed IOCTL in MxGeneralIo Utility Enables Privilege Escalation and DoS

An exposed IOCTL with an  insufficient access control vulnerability has been identified in the utility, MxGeneralIo, for Moxa’s industrial x86 computers. The affected utility, MxGeneralIo, exposes IOCTL methods that permit direct read and write access to MSR and system memory. A local attacker with high privileges could abuse these interfaces to perform unauthorized operations. Successful exploitation may result in privilege escalation on Windows 7 systems or cause a system crash (BSoD) on Windows 10 and 11 systems, leading to a denial-of-service condition. The vulnerability could slightly affect the confidentiality and integrity of the device, but availability might be heavily impacted. No impact to the subsequent system has been identified.

CVSS 4.0 · 7 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-41313

A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="switch_contact"

CVSS 3.1 · 5.4 Medium EPSS 1.1% KEV · Not listed
Vendors
CVE-2022-41312

A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="Switch Description", name "switch_description"

CVSS 3.1 · 5.4 Medium EPSS 1.1% KEV · Not listed
Vendors
CVE-2022-41311

A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="webLocationMessage_text" name="webLocationMessage_text"

CVSS 3.1 · 5.4 Medium EPSS 1.1% KEV · Not listed
Vendors
CVE-2016-9354

An issue was discovered in Moxa DACenter Versions 1.4 and older. A specially crafted project file may cause the program to crash because of Uncontrolled Resource Consumption.

CVSS 3.0 · 5.5 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2016-9346

An issue was discovered in Moxa MiiNePort E1 versions prior to 1.8, E2 versions prior to 1.4, and E3 versions prior to 1.1. Configuration data are stored in a file that is not encrypted.

CVSS 3.0 · 5.3 Medium EPSS 1.2% KEV · Not listed
Vendors
CVE-2016-9344

An issue was discovered in Moxa MiiNePort E1 versions prior to 1.8, E2 versions prior to 1.4, and E3 versions prior to 1.1. An attacker may be able to brute force an active session cookie to be able to download configuration files.

CVSS 3.0 · 7.5 High EPSS 1.6% KEV · Not listed
Vendors
CVE-2016-9333

An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. The SoftCMS Application does not properly sanitize input that may allow a remote attacker access to SoftCMS with administrator's privilege through specially crafted input (SQL INJECTION).

CVSS 3.0 · 9.8 Critical EPSS 1.9% KEV · Not listed
Vendors
Products
CVE-2016-9332

An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. Moxa SoftCMS Webserver does not properly validate input. An attacker could provide unexpected values and cause the program to crash or excessive consumption of resources could result in a denial-of-service condition.

CVSS 3.0 · 7.5 High EPSS 8.2% KEV · Not listed
Vendors
Products
CVE-2016-8727

An exploitable information disclosure vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point. Retrieving a series of URLs without authentication can reveal sensitive configuration and system information to an attacker.

CVSS 3.0 · 7.5 High EPSS 1.7% KEV · Not listed
Vendors
CVE-2017-7915

An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. An attacker can freely use brute force to determine parameters needed to bypass authentication.

CVSS 3.0 · 9.8 Critical EPSS 1.5% KEV · Not listed
Vendors
CVE-2016-8726

An exploitable null pointer dereference vulnerability exists in the Web Application /forms/web_runScript iw_filename functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. An HTTP POST request with a blank line in the header will cause a segmentation fault in the web server.

CVSS 3.1 · 7.5 High EPSS 1.4% KEV · Not listed
Vendors
CVE-2016-8725

An exploitable information disclosure vulnerability exists in the Web Application functionality of the Moxa AWK-3131A wireless access point running firmware 1.1. Retrieving a specific URL without authentication can reveal sensitive information to an attacker.

CVSS 3.1 · 5.3 Medium EPSS 1.3% KEV · Not listed
Vendors
CVE-2016-9348

An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. A configuration file contains parameters that represent passwords in plaintext.

CVSS 3.0 · 3.3 Low EPSS < 1% KEV · Not listed
Vendors
CVE-2017-7913

A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application's configuration file contains parameters that represent passwords in plaintext.

CVSS 3.0 · 9.8 Critical EPSS 1.2% KEV · Not listed
Vendors
CVE-2017-7917

A Cross-Site Request Forgery issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application does not sufficiently verify if a request was intentionally provided by the user who submitted the request, which could allow an attacker to modify the configuration of the device.

CVSS 3.0 · 8.8 High EPSS < 1% KEV · Not listed
Vendors