Weak Password Requirements in Kiloview P1/P2 devices
The user management section of the web application permits the creation of user accounts with excessively weak passwords, including single-character passwords.
The user management section of the web application permits the creation of user accounts with excessively weak passwords, including single-character passwords.
zot is ancontainer image/artifact registry based on the Open Container Initiative Distribution Specification. Prior to version 2.1.3 (corresponding to pseudoversion 1.4.4-0.20250522160828-8a99a3ed231f), when using Keycloak as an oidc provider, the clientsecret gets printed into the container stdout logs for an example at container startup. Version 2.1.3 (corresponding to pseudoversion 1.4.4-0.20250522160828-8a99a3ed231f) fixes the issue.
Deserialization of untrusted data can occur in versions of the Keras framework running versions 3.11.0 up to but not including 3.11.3, enabling a maliciously uploaded Keras file containing a TorchModuleWrapper class to run arbitrary code on an end user’s system when loaded despite safe mode being enabled. The vulnerability can be triggered through both local and remote files.
wire-ios is an iOS client for the Wire secure messaging application. From Wire iOS 3.111.1 to before 3.124.1, messages that were visible in the view port have been logged to the iOS system logs in clear text. Wire application logs created and managed by the application itself were not affected, especially not the logs users can export and send to Wire support. The iOS logs can only be accessed if someone had (physical) access to the underlying unlocked device. The issue manifested itself by calling canOpenUrl() and passing an invalid URL object. When iOS then performs the check and fails, it logs the contents to the system log. This is not documented behaviour. Wire released an emergency fix with version 3.124.1. As a workaround, users can reset their iOS device to remove the offending logs. Since Wire cannot access or modify iOS system logs, there's no other workaround other than a reset.
Files or directories accessible to external parties issue exists in SS1 Ver.16.0.0.10 and earlier (Media version:16.0.0a and earlier). If exploited, uploaded files and SS1 configuration files may be accessed by a remote unauthenticated attacker.
Insertion of sensitive information into log file issue exists in "region PAY" App for Android prior to 1.5.28. If exploited, sensitive user information may be exposed to an attacker who has access to the application logs.
A vulnerability has been identified in SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 8), SIMATIC STEP 7 V18 (All versions < V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 8), SIMATIC WinCC Unified V18 (All versions < V18 SP5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 8), SIMATIC WinCC V18 (All versions < V18 SP5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions < V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V4.6.0.1), TIA Portal Cloud V18 (All versions < V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
Deserialization of Untrusted Data vulnerability in Tijmen Smit WP Store Locator wp-store-locator allows Object Injection.This issue affects WP Store Locator: from n/a through <= 2.2.260.
Deserialization of Untrusted Data vulnerability in Hernan Villanueva Boldermail boldermail allows Object Injection.This issue affects Boldermail: from n/a through <= 2.4.0.
A path traversal vulnerability has been reported to affect several product versions. If a local attacker gains a user account, they can then exploit the vulnerability to read the contents of unexpected files or system data. We have already fixed the vulnerability in the following versions: Qfinder Pro Mac 7.13.0 and later Qsync for Mac 5.1.5 and later QVPN Device Client for Mac 2.2.8 and later
"SwitchBot" App for iOS/Android contains an insertion of sensitive information into log file vulnerability in versions V6.24 through V9.12. If this vulnerability is exploited, sensitive user information may be exposed to an attacker who has access to the application logs.
A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
There is a deserialization of untrusted data vulnerability in the Kredis JSON deserialization code
Insertion of sensitive information into log file for some Intel(R) Local Manageability Service software before version 2316.5.1.2 may allow an authenticated user to potentially enable information disclosure via local access.
pac4j is a security framework for Java. `pac4j-core` prior to version 4.0.0 is affected by a Java deserialization vulnerability. The vulnerability affects systems that store externally controlled values in attributes of the `UserProfile` class from pac4j-core. It can be exploited by providing an attribute that contains a serialized Java object with a special prefix `{#sb64}` and Base64 encoding. This issue may lead to Remote Code Execution (RCE) in the worst case. Although a `RestrictedObjectInputStream` is in place, that puts some restriction on what classes can be deserialized, it still allows a broad range of java packages and potentially exploitable with different gadget chains. pac4j versions 4.0.0 and greater are not affected by this issue. Users are advised to upgrade. There are no known workarounds for this vulnerability.
No password for the root user is set in Novakon P series. This allows phyiscal attackers to enter the console easily. This issue affects P series: P – V2001.A.C518o2 until P-2.0.05 Build 2026.02.06 (commit d0f97fd9).
A link following vulnerability exists in the UnifyScanner component of Armoury Crate. This vulnerability may be triggered by creating a specially crafted junction, potentially leading to local privilege escalation. For more information, please refer to section 'Security Update for Armoury Crate App' in the ASUS Security Advisory.
Himmelblau is an interoperability suite for Microsoft Azure Entra ID and Intune. When debugging is enabled for Himmelblau in version 1.0.0, the himmelblaud_tasks service leaks an Intune service access token to the system journal. This short-lived token can be used to detect the host's Intune compliance status, and may permit additional administrative operations for the Intune host device (though the API for these operations is undocumented). This is fixed in version 1.1.0. To workaround this issue, ensure that Himmelblau debugging is disabled.
A vulnerability has been identified in the way that Rancher stores vSphere's CPI (Cloud Provider Interface) and CSI (Container Storage Interface) credentials used to deploy clusters through the vSphere cloud provider. This issue leads to the vSphere CPI and CSI passwords being stored in a plaintext object inside Rancher. This vulnerability is only applicable to users that deploy clusters in vSphere environments.