An invalid memory access when handling the ProtocolIE_ID field of S1Setup Request messages in Athonet vEPC MME v11.4.0 allows attackers to cause a Denial of Service (DoS) to the cellular network by repeatedly initiating connections and sending a crafted payload.
Search vulnerabilities
An issue in Netis Wifi6 Router NX10 2.0.1.3643 and 2.0.1.3582 and Netis Wifi 11AC Router NC65 3.0.0.3749 and Netis Wifi 11AC Router NC63 3.0.0.3327 and 3.0.0.3503 and Netis Wifi 11AC Router NC21 3.0.0.3800, 3.0.0.3500 and 3.0.0.3329 and Netis Wifi Router MW5360 1.0.1.3442 and 1.0.1.3031 allows a remote attacker to obtain sensitive information via the parameter password at the change admin password page at the router web interface.
CODESYS Control - Linux/QNX SysSocket flaw
An unauthenticated remote attacker, who beats a race condition, can exploit a flaw in the communication servers of the CODESYS Control runtime system on Linux and QNX to trigger an out-of-bounds read via crafted socket communication, potentially causing a denial of service.
ruby: Arbitrary memory address read vulnerability with Regex search
An issue was discovered in Ruby 3.x through 3.3.0. If attacker-supplied data is provided to the Ruby regex compiler, it is possible to extract arbitrary heap data relative to the start of the text, including pointers and sensitive strings. The fixed versions are 3.0.7, 3.1.5, 3.2.4, and 3.3.1.
A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain an out-of-bounds read in the memory dump function. This could allow an attacker with Medium (MED) or higher privileges to cause the device to enter an insecure cold start state.
Holy Stone Remote ID Module HSRID01, firmware distributed with the Drone Go2 mobile application before 1.1.8, allows unauthenticated "remote power off" actions (in broadcast mode) via multiple read operations on the ASTM Remote ID (0xFFFA) GATT.
Lorex 2K Indoor Wi-Fi Security Camera - Out of bounds heap read
An unauthenticated attacker can perform an out of bounds heap read in the IQ Service (TCP port 9876). This vulnerability has been resolved in firmware version 2.800.0000000.8.R.20241111.
Firepad through 1.5.11 allows remote attackers, who have knowledge of a pad ID, to retrieve both the current text of a document and all content that has previously been pasted into the document. NOTE: in several similar products, this is the intentional behavior for anyone who knows the full document ID and corresponding URL. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
OpenZeppelin Contracts's Bytes's lastIndexOf function with position argument performs out-of-bound memory access on empty buffers
OpenZeppelin Contracts is a library for secure smart contract development. Starting in version 5.2.0 and prior to version 5.4.0, the `lastIndexOf(bytes,byte,uint256)` function of the `Bytes.sol` library may access uninitialized memory when the following two conditions hold: 1) the provided buffer length is empty (i.e. `buffer.length == 0`) and position is not `2**256 - 1` (i.e. `pos != type(uint256).max`). The `pos` argument could be used to access arbitrary data outside of the buffer bounds. This could lead to the operation running out of gas, or returning an invalid index (outside of the empty buffer). Processing this invalid result for accessing the `buffer` would cause a revert under normal conditions. When triggered, the function reads memory at offset `buffer + 0x20 + pos`. If memory at that location (outside the `buffer`) matches the search pattern, the function would return an out of bound index instead of the expected `type(uint256).max`. This creates unexpected behavior where callers receive a valid-looking index pointing outside buffer bounds. Subsequent memory accesses that don't check bounds and use the returned index must carefully review the potential impact depending on their setup. Code relying on this function returning `type(uint256).max` for empty buffers or using the returned index without bounds checking could exhibit undefined behavior. Users should upgrade to version 5.4.0 to receive a patch.
Potential heap-based buffer over-read vulnerability in NotepadNext
Out-of-bounds Read vulnerability in dail8859 NotepadNext (src/lua/src modules). This vulnerability is associated with program files lparser.C. This issue affects NotepadNext: through v0.11. The singlevar() in lparser.c lacks a certain luaK_exp2anyregup call, leading to a heap-based buffer over-read that might affect a system that compiles untrusted Lua code.
microcode_ctl: Improper restriction of software interfaces to hardware features
Improper restriction of software interfaces to hardware features for some Intel(R) Xeon(R) 6 processor with E-cores when using Intel(R) Trust Domain Extensions (Intel(R) TDX) or Intel(R) Software Guard Extensions (Intel(R) SGX) may allow a privileged user to potentially enable escalation of privilege via local access.
An issue in Netis Wifi6 Router NX10 2.0.1.3643 and 2.0.1.3582 and Netis Wifi 11AC Router NC65 3.0.0.3749 and Netis Wifi 11AC Router NC63 3.0.0.3327 and 3.0.0.3503 and Netis Wifi 11AC Router NC21 3.0.0.3800, 3.0.0.3500 and 3.0.0.3329 and Netis Wifi Router MW5360 1.0.1.3442 and 1.0.1.3031 allows a remote attacker to obtain sensitive information via the endpoint /cgi-bin/skk_set.cgi and binary /bin/scripts/start_wifi.sh
mmstu.c in VideoLAN VLC media player before 3.0.22 allows an out-of-bounds read and denial of service via a crafted 0x01 response from an MMS server.
PCSX2 has an Out-of-bounds Read due to unchecked offset and size passed to memcpy
PCSX2 is a free and open-source PlayStation 2 (PS2) emulator. In versions 2.5.377 and below, an unchecked offset and size used in a memcpy operation inside PCSX2's CDVD SCMD 0x91 and SCMD 0x8F handlers allow a specially crafted disc image or ELF to cause an out-of-bounds read from emulator memory. Because the offset and size is controlled through MG header fields, a specially crafted ELF can read data beyond the bounds of mg_buffer and have it reflected back into emulated memory. This issue is fixed in version 2.5.378.
Out-Of-Bounds Read affecting the PAR file reading procedure in SOLIDWORKS eDrawings on Release SOLIDWORKS Desktop 2025
An Out-Of-Bounds Read vulnerability affecting the PAR file reading procedure in SOLIDWORKS eDrawings on Release SOLIDWORKS Desktop 2025 could allow an attacker to execute arbitrary code while opening a specially crafted PAR file.
DjVuLibre OOB-Write Vulnerability in MMRDecoder
DjVuLibre is a GPL implementation of DjVu, a web-centric format for distributing documents and images. Prior to version 3.5.29, the MMRDecoder::scanruns method is affected by an OOB-write vulnerability, because it does not check that the xr pointer stays within the bounds of the allocated buffer. This can lead to writes beyond the allocated memory, resulting in a heap corruption condition. An out-of-bounds read with pr is also possible for the same reason. This issue has been patched in version 3.5.29.
kernel: USB: improper validation of wMaxPacketValue entries in endpoint descriptors
In the Linux kernel before 4.8, usb_parse_endpoint in drivers/usb/core/config.c does not validate the wMaxPacketSize field of an endpoint descriptor. NOTE: This vulnerability only affects products that are no longer supported by the supplier.
Out-of-bounds Read in nr flc
Out-of-bounds Read vulnerability in ASR1903、ASR3901 in ASR Lapwing_Linux on Linux (nr_fw modules). This vulnerability is associated with program files Code/nr_fw/DLP/src/NrCgi.C. This issue affects Lapwing_Linux: before 2025/11/26.
A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions), Cerberus PRO EN Fire Panel FC72x IP6 (All versions), Cerberus PRO EN Fire Panel FC72x IP7 (All versions), Cerberus PRO EN Fire Panel FC72x IP8 (All versions < IP8 SR4), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.3.5618), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.3.5617), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions), Sinteso FS20 EN Fire Panel FC20 MP8 (All versions < MP8 SR4), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.3.5618), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.3.5617), Sinteso Mobile (All versions). The network communication library in affected systems insufficiently validates HMAC values which might result in a buffer overread. This could allow an unauthenticated remote attacker to crash the network service.
An uninitialized stack read issue exists in Amazon Ion-C versions <v1.1.4 that may allow a threat actor to craft data and serialize it to Ion text in such a way that sensitive data in memory could be exposed through UTF-8 escape sequences. To mitigate this issue, users should upgrade to version v1.1.4.