The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on a certain port. After accessing the network between the indoor and outdoor units of the CPE, an attacker can deliver commands to the specific port of the outdoor unit and execute them without authentication. Successful exploit could allow the attacker to take control over the outdoor unit.
Search vulnerabilities
An issue was discovered in Logpoint before 7.5.0. An endpoint used by Distributed Logpoint Setup was exposed, allowing unauthenticated attackers to bypass CSRF protections and authentication.
CHANNEL ACCESSIBLE BY NON-ENDPOINT CWE-300
Aethon TUG Home Base Server versions prior to version 24 are affected by un unauthenticated attacker who can freely access hashed user credentials.
Emerson DeltaV Missing Authentication for Critical Function
A specially crafted script could cause the DeltaV Distributed Control System Controllers (All Versions) to restart and cause a denial-of-service condition.
Ovarro TBox Insufficiently Protected Credentials
An attacker can decrypt the Ovarro TBox login password by communication capture and brute force attacks.
CodeAstro House Rental Management System tenant.php missing authentication
A vulnerability was found in CodeAstro House Rental Management System 1.0. It has been rated as problematic. Affected by this issue is some unknown functionality of the file booking.php/owner.php/tenant.php. The manipulation leads to missing authentication. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-255392.
AVEVA System Platform Missing Authentication for Critical Function
AVEVA System Platform versions 2017 through 2020 R2 P01 does not perform any authentication for functionality that requires a provable user identity.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges.
Fresenius Kabi Agilia Connect Infusion System files or directories accessible to external parties
Fresenius Kabi Agilia SP MC WiFi vD25 and prior has a default configuration page accessible without authentication. An attacker may use this functionality to change the exposed configuration values such as network settings.
ICSA-20-140-02 Emerson OpenEnterprise
Emerson OpenEnterprise versions through 3.3.4 may allow an attacker to run an arbitrary commands with system privileges or perform remote code execution via a specific communication service.
ICSA-22-063-01 Missing Authentication for Critical Function in Trailer Power Line Communications (PLC) J2497
Power Line Communications PLC4TRUCKS J2497 trailer brake controllers implement diagnostic functions which can be invoked by replaying J2497 messages. There is no authentication or authorization for these functions.
PTC Axeda agent and Axeda Desktop Server Missing Authentication For Critical Function
Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain commands to a specific port without authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to obtain full file-system access and remote code execution.
PTC Axeda agent and Axeda Desktop Server Missing Authentication For Critical Function
When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send a certain command to a specific port without authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to shut down a specific service.
PTC Axeda agent and Axeda Desktop Server Missing Authentication For Critical Function
When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain XML messages to a specific port without proper authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to read and modify the affected product’s configuration.
ICSMA-22-088-01 Philips e-Alert
The software does not perform any authentication for critical system functionality.
ICSA-20-147-01 Inductive Automation Ignition (Update B)
Sensitive information can be obtained through the handling of serialized data. The issue results from the lack of proper authentication required to query the server
3.2.4 IMPROPER ACCESS CONTROL CWE-284
LRM does not implement authentication or authorization by default. A malicious actor can inject, replay, modify, and/or intercept sensitive data.
ICSA-22-200-01 MiCODUS MV720 GPS tracker Improper Authentication
SMS-based GPS commands can be executed by MiCODUS MV720 GPS tracker without authentication.
Advantech iView
The affected product is vulnerable due to missing authentication, which may allow an attacker to read or modify sensitive data and execute arbitrary code, resulting in a denial-of-service condition.
Cognex 3D-A1000 Dimensioning System Missing Authentication for Critical Function
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.