There is a password verification vulnerability in WS7200-10 11.0.2.13. Attackers on the LAN may use brute force cracking to obtain passwords, which may cause sensitive system information to be disclosed.
Search vulnerabilities
Missing Role Based Access Control for the REST handlers in bleve/http package
Bleve is a text indexing library for go. Bleve includes HTTP utilities under bleve/http package, that are used by its sample application. These HTTP methods pave way for exploitation of a node’s filesystem where the bleve index resides, if the user has used bleve’s own HTTP (bleve/http) handlers for exposing the access to the indexes. For instance, the CreateIndexHandler (`http/index_create.go`) and DeleteIndexHandler (`http/index_delete.go`) enable an attacker to create a bleve index (directory structure) anywhere where the user running the server has the write permissions and to delete recursively any directory owned by the same user account. Users who have used the bleve/http package for exposing access to bleve index without the explicit handling for the Role Based Access Controls(RBAC) of the index assets would be impacted by this issue. Version 2.5.0 relocated the `http/` dir used _only_ by bleve-explorer to `blevesearch/bleve-explorer`, thereby addressing the issue. However, the http package is purely intended to be used for demonstration purposes. Bleve was never designed handle the RBACs, nor it was ever advertised to be used in that way. The collaborators of this project have decided to stay away from adding any authentication or authorization to bleve project at the moment. The bleve/http package is mainly for demonstration purposes and it lacks exhaustive validation of the user inputs as well as any authentication and authorization measures. It is recommended to not use bleve/http in production use cases.
erlang/otp: Client Authentication Bypass
In Erlang/OTP before 23.3.4.15, 24.x before 24.3.4.2, and 25.x before 25.0.2, there is a Client Authentication Bypass in certain client-certification situations for SSL, TLS, and DTLS.
Authentication Bypass in OpenPubKey
Versions of OpenPubkey library prior to 0.10.0 contained a vulnerability that would allow a specially crafted JWS to bypass signature verification.
Medtronic Conexus Radio Frequency Telemetry Protocol Improper Access Control
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.
Authentication Bypass in OPKSSH
Versions of OpenPubkey library prior to 0.10.0 contained a vulnerability that would allow a specially crafted JWS to bypass signature verification. As OPKSSH depends on the OpenPubkey library for authentication, this vulnerability in OpenPubkey also applies to OPKSSH versions prior to 0.5.0 and would allow an attacker to bypass OPKSSH authentication.
Omron CJ-series and CS-series unauthenticated filesystem access.
An attacker with network access to the affected PLC (CJ-series and CS-series PLCs, all versions) may use a network protocol to read and write files on the PLC internal memory and memory card.
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle WebLogic Server accessible data. CVSS 3.1 Base Score 7.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
A vulnerability exists in the UNEM server / APIGateway that if exploited allows a malicious user to perform an arbitrary number of authentication attempts using different passwords, and eventually gain access to other components in the same security realm using the targeted account.
OpenCTI's lack of Rate Limit lead to OTP brute forcing
OpenCTI is an open-source cyber threat intelligence platform. In versions below 6.2.18, because the function to limit the rate of OTP does not exist, an attacker with valid credentials or a malicious user who commits internal fraud can break through the two-factor authentication and hijack the account. This is because the otpLogin mutation does not implement One Time Password rate limiting. As of time of publication, it is unknown whether a patch is available.
WiJungle NGFW Version U250 was discovered to be vulnerable to No Rate Limit attack, allowing the attacker to brute force the admin password leading to Account Take Over.
HCL MyXalytics is affected by concurrent login vulnerability
HCL MyXalytics is affected by concurrent login vulnerability. A concurrent login vulnerability occurs when simultaneous active sessions are allowed for a single credential allowing an attacker to potentially obtain access to a user's account or sensitive information.
HCL MyXalytics is affected by a failure to restrict URL access vulnerability
HCL MyXalytics is affected by a failure to restrict URL access vulnerability. Unauthenticated users might gain unauthorized access to potentially confidential information, creating a risk of misuse, manipulation, or unauthorized distribution.
MachineSense FeverWarn Missing Authentication for Critical Function
The cloud provider MachineSense uses for integration and deployment for multiple MachineSense devices, such as the programmable logic controller (PLC), PumpSense, PowerAnalyzer, FeverWarn, and others is insufficiently protected against unauthorized access. An attacker with access to the internal procedures could view source code, secret credentials, and more.
Dell EMC XtremIO versions prior to X2 6.4.0-22 contain a bruteforce vulnerability. A remote unauthenticated attacker can potentially exploit this vulnerability and gain access to an admin account.
Boodskap IoT Platform v4.4.9-02 allows attackers to make unauthenticated API requests.
An issue in GX Group GPON ONT Titanium 2122A T2122-V1.26EXL allows attackers to escalate privileges via a brute force attack at the login page.
An issue has been discovered in GitLab CE/EE affecting all versions before 15.1.6, all versions starting from 15.2 before 15.2.4, all versions starting from 15.3 before 15.3.2. It may be possible for an attacker to guess a user's password by brute force by sending crafted requests to a specific endpoint, even if the victim user has 2FA enabled on their account.
An issue in Horizon Business Services Inc. Caterease 16.0.1.1663 through 24.0.1.2405 and possibly later versions, allows a local attacker to perform a Password Brute Forcing attack due to improper restriction of excessive authentication attempts.
D-Link DIR-X3260 prog.cgi Incorrect Implementation of Authentication Algorithm Authentication Bypass Vulnerability
D-Link DIR-X3260 prog.cgi Incorrect Implementation of Authentication Algorithm Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of D-Link DIR-X3260 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the prog.cgi executable. The issue results from an incorrect implementation of the authentication algorithm. An attacker can leverage this vulnerability to bypass authentication on the device. Was ZDI-CAN-21100.