Search vulnerabilities

Results 4,628

Export CSV
CVE-2025-7416

Tenda O3V2 httpd setSysTimeInfo fromSysToolTime stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda O3V2 1.0.0.12(3880). Affected is the function fromSysToolTime of the file /goform/setSysTimeInfo of the component httpd. The manipulation of the argument Time leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2025-7527

Tenda FH1202 AdvSetWan fromAdvSetWan stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects the function fromAdvSetWan of the file /goform/AdvSetWan. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2025-7528

Tenda FH1202 GstDhcpSetSer fromGstDhcpSetSer stack-based overflow

A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2025-7529

Tenda FH1202 Natlimit fromNatlimit stack-based overflow

A vulnerability classified as critical was found in Tenda FH1202 1.2.0.14(408). Affected by this vulnerability is the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2025-7530

Tenda FH1202 PPTPDClient fromPptpUserAdd stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14(408). Affected by this issue is the function fromPptpUserAdd of the file /goform/PPTPDClient. The manipulation of the argument Username leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2025-7531

Tenda FH1202 PPTPUserSetting fromPptpUserSetting stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). This affects the function fromPptpUserSetting of the file /goform/PPTPUserSetting. The manipulation of the argument delno leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS 1.3% KEV · Not listed
Vendors
CVE-2025-7532

Tenda FH1202 webExcptypemanFilter fromwebExcptypemanFilter stack-based overflow

A vulnerability has been found in Tenda FH1202 1.2.0.14(408) and classified as critical. This vulnerability affects the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS 1.3% KEV · Not listed
Vendors
CVE-2025-7544

Tenda AC1206 setMacFilterCfg formSetMacFilterCfg stack-based overflow

A vulnerability was found in Tenda AC1206 15.03.06.23. It has been rated as critical. This issue affects the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS 1.8% KEV · Not listed
Vendors
CVE-2025-7598

Tenda AX1803 setWifiFilterCfg formSetWifiMacFilterCfg stack-based overflow

A vulnerability classified as critical was found in Tenda AX1803 1.0.0.1. Affected by this vulnerability is the function formSetWifiMacFilterCfg of the file /goform/setWifiFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2025-7602

D-Link DI-8100 HTTP Request arp_sys.asp stack-based overflow

A vulnerability was found in D-Link DI-8100 16.07.26A1 and classified as critical. This issue affects some unknown processing of the file /arp_sys.asp of the component HTTP Request Handler. The manipulation leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.6 High EPSS 1.3% KEV · Not listed
Vendors
CVE-2025-7603

D-Link DI-8100 HTTP Request jingx.asp stack-based overflow

A vulnerability was found in D-Link DI-8100 16.07.26A1. It has been classified as critical. Affected is an unknown function of the file /jingx.asp of the component HTTP Request Handler. The manipulation leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.6 High EPSS 1.3% KEV · Not listed
Vendors
CVE-2025-7548

Tenda FH1201 SafeEmailFilter formSafeEmailFilter stack-based overflow

A vulnerability has been found in Tenda FH1201 1.2.0.14(408) and classified as critical. This vulnerability affects the function formSafeEmailFilter of the file /goform/SafeEmailFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2025-7549

Tenda FH1201 L7Prot frmL7ProtForm stack-based overflow

A vulnerability was found in Tenda FH1201 1.2.0.14(408) and classified as critical. This issue affects the function frmL7ProtForm of the file /goform/L7Prot. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2025-7550

Tenda FH1201 GstDhcpSetSer fromGstDhcpSetSer stack-based overflow

A vulnerability was found in Tenda FH1201 1.2.0.14(408). It has been classified as critical. Affected is the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2025-7551

Tenda FH1201 PPTPDClient fromPptpUserAdd stack-based overflow

A vulnerability was found in Tenda FH1201 1.2.0.14(408). It has been declared as critical. Affected by this vulnerability is the function fromPptpUserAdd of the file /goform/PPTPDClient. The manipulation of the argument modino/username leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS 1.3% KEV · Not listed
Vendors
CVE-2024-9284

TP-LINK TL-WR841ND popupSiteSurveyRpm.htm stack-based overflow

A vulnerability was found in TP-LINK TL-WR841ND up to 20240920. It has been rated as critical. Affected by this issue is some unknown functionality of the file /userRpm/popupSiteSurveyRpm.htm. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 4.0 · 7.1 High EPSS < 1% KEV · Not listed
Vendors
CVE-2025-7597

Tenda AX1803 setMacFilterCfg formSetMacFilterCfg stack-based overflow

A vulnerability classified as critical has been found in Tenda AX1803 1.0.0.1. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2025-7505

Tenda FH451 HTTP POST Request L7Prot frmL7ProtForm stack-based overflow

A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Affected is the function frmL7ProtForm of the file /goform/L7Prot of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS 1.0% KEV · Not listed
Vendors
CVE-2025-7506

Tenda FH451 HTTP POST Request Natlimit fromNatlimit stack-based overflow

A vulnerability classified as critical was found in Tenda FH451 1.0.0.9. Affected by this vulnerability is the function fromNatlimit of the file /goform/Natlimit of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS 1.0% KEV · Not listed
Vendors
CVE-2024-4171

Tenda W30E WizardHandle fromWizardHandle stack-based overflow

A vulnerability classified as critical has been found in Tenda W30E 1.0/1.0.1.25. Affected is the function fromWizardHandle of the file /goform/WizardHandle. The manipulation of the argument PPW leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261990 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 8.8 High EPSS 1.4% KEV · Not listed
Vendors
Products